The Glass-electrodes Method Evaluating the Efficiency of Scale Inhibitors
Author(s):
ZhaoZhiren LeiWu XiaMingzhu WangFengyun
School of Chemical Engineering,NUST,Nanjing 210094
Keywords:
ant isludg ing agents bubbing performance testing glass elect rodes
PACS:
O657.1
DOI:
-
Abstract:
The g lass-electrode method ( GEM) evaluating the eff iciency of scale inhibitors by the changes of hydrogen ion in the test sample has been described. Compared w ith the classic methods such as the stat ic and the aerat ion method, the new method has many virtues. The standard relative deviat ion of GEM is only 50% that of the aeration. It w ill take only 30 minutes to finish relative to the over 6 hours of the aerat ion. With the very simple equipment , it is very easy to be operated, and the ex cellent accuracy can be achieved.

References:

1 中国石油化工总公司. 冷却水分析和试验方法. 北京: 石油出版社, 1993. 371~ 374
2 周本省, 杨金相, 陆建英等. 水处理药剂阻垢性能测定方法——鼓泡法1 中华人民共和国化工行业标准HG/ T 2094- 91, 1991. 北京: 中国标准出版社, 1996. 114~ 117
3 张青, 吴文辉. 临界pH 在阻垢剂研究中的应用. 工业水处理, 1997, 17( 1) : 33~ 34