|Table of Contents|

Study of Temperature Correction for Pressure-measuring Copper Cylinder Based on Quasi-dynamic Calibration(PDF)

《南京理工大学学报》(自然科学版)[ISSN:1005-9830/CN:32-1397/N]

Issue:
2003年03期
Page:
261-264
Research Field:
Publishing date:

Info

Title:
Study of Temperature Correction for Pressure-measuring Copper Cylinder Based on Quasi-dynamic Calibration
Author(s):
KongDeren PuJian ZhangShuning ZhuMingwu
School of Mechanical Engineering,NUST,Nanjing 210094
Keywords:
copper cylinder temperature coef ficient regression analysis quas-i dynamic cal-i brat ion pressure-measuring
PACS:
TH823
DOI:
-
Abstract:
The methods of common temperature correct ion , the meaning of quas-i dynamic calibrat ion on copper cylinders and the method of making table of copper cylinders are presented. Data of quas-i dynamic calibrat ion for pressure-measuring copper cylinder under a different temperature are analyzed. According to the calibrat ion data, temperature correct ing formula is derived by reg ression analysis. It is testified by the experiment s on drop-hammer dynamic pressure calibration system that the formula is feasible. T his formula can be used to calculate the correct ing value of pressure w hen copper cylinders work under nonstandard temperature . It can also be used to make temperature correct ing table.

References:

1 王仁. 塑性力学进展[M] . 北京: 中国铁道出版社, 1988.
2 朱明武. 测压铜柱准动态标定实践[ J] . 兵工学报, 1993( 3) : 80~ 83.
3 孔德仁, 张淑宁. 测压铜球的温度统一修正方法探讨[ J] . 南京理工大学学报, 2003,27( 1) : 52~ 55.
4 程曙霞. 工程试验理论简明教程[M] . 合肥: 中国科学技术大学出版社, 2000.