Metering Correlation of Slotted Orifice for Low-pressure Wet Gas Flow
Author(s):
HUA Chen-quan12WANG Chang-ming1GENG Yan-feng2WANG Xiao-zhi2
1.School of Mechanical Engineering,NUST,Nanjing 210094,China;2.College of Information & Control Engineering,China University of Petroleum,Dongying 257061,China
Keywords:
wet gas slotted orifice metering correlation gas Froude Number gas to liquid density ratio
PACS:
O359.1;TP216.1
DOI:
-
Abstract:
A slotted orifice in wet gas metering is required to find out a correlation to correct the liquid-induced over-reading.The wet gas response of the horizontally installed slotted orifice with 0.50 beta ratio is experimentally studied.After studying the relationship between the over-reading and Lockhart-Martinelli parameter,gas Froude number,the gas to liquid density ratio,a novel metering correlation for low-pressure wet gas flow is given.The results show that the new correlation corrects the liquid induced gas flow rate prediction error of the wet gas flow to ±4% at a 97% confidence level,with the conditions of pressure from 0.25 MPa to 0.35 MPa,Lockhart-Martinelli parameter from 0.02 to 0.6,and the gas Froude number from 0.5 to 2.7,which is distinctly more precise than other correlations of the slotted orifice.

References:

[ 1] ?? 耿艳峰, 冯叔初, 郑金吾, 等. 凝析天然气计量技 术[ J] . 自动化仪表, 2005, 26( 8): 1- 3.
[ 2] M ehdizadeh P. W et gas me tering: Trends in app lications and technica l deve lopm ents[A ]. SPE 77351[ C]. San Antonio, Texas, USA: Soc iety of Pe tro leum Eng-i neers Inc, 2002.
[ 3] M urdock JW. Tw o-phase flow measurem ents w ith or-i fices[ J]. Basic Eng ineer, 1962, 84( 4): 419- 433.
[ 4] Fang L D, Zhang T. Pe rfo rm ance o f a ho rizontally m ounted ventur i in low-pressure w et gas flow [ J ]. Ch inese Journa l o f Chem ica l Eng ineering, 2008, 16( 2) : 320- 324.
[ 5] De Leeuw R. Liquid co rrection of V enturi m eter readings in w et gas flow [ R]. No rth sea w orkshop, Paper 21, 1997.
[ 6] Steven R. W et gas me tering w ith a hor izonta llym oun-t ed Ven tur i me ter[ J]. F low m easurement and Instrum en tation, 2002( 12): 361- 372.
[ 7] M orrison G L, H a ll K R. Com par ison o f orifice and slotted p la te flowme ters[ J] . Flow M easurem ent and Instrum enta tion, 1994, 5( 2): 71- 77.
[ 8] M orr ison G L, Terracina D, Brewer C, et a.l Response o f a slotted or ifice flow m e ter to an a ir /wa ter m ixture[ J]. Flow M easurem ent and Instrum entation, 2001, 12( 3): 175- 180.
[ 9] Geng Y F, Feng S C. S tudy on a new type of sensor for w et gas me ter[ A ]. The 4th In ternationa l Sympo sium on M easurement Techn iques fo r M ultiphase Flow s [ C ]. Be ijing: International Academ ic Publishers, 2004: 536 - 541.
[ 10] Geng Y F, Zheng JW, ShiT M. S tudy on them eter ing character istics o f slotted or ifice fo r w et gas flow [ J]. Flow Measurement and Instrum entation, 2006 ( 17 ): 123- 128.
[ 11] 邢兰昌, 耿艳峰, 孙苗苗. 一种新的低含液率气液 两相流槽式孔板压降倍率相关式[ J]. 中国电机工 程学报, 2008, 28( 14): 86- 90.

Memo

Memo:
-
Last Update: 2012-11-02