|Table of Contents|

Determination Formaldehyde in Indoor Air by Simultaneous Prosess of Collection and On-ACF Derivatization and Thermal Desorption-capillary Gas Chromatography

《南京理工大学学报》(自然科学版)[ISSN:1005-9830/CN:32-1397/N]

Issue:
2011年02期
Page:
262-267
Research Field:
Publishing date:

Info

Title:
Determination Formaldehyde in Indoor Air by Simultaneous Prosess of Collection and On-ACF Derivatization and Thermal Desorption-capillary Gas Chromatography
Author(s):
WANG Yu-Qun12WANG Zheng-ping2
1.Testing Center for Quality of Construction Engineering,Jiangsu Institute of Building Science,Nanjing 210008,China;2.School of Chemcial Engineering,NUST,Nanjing 210094,China
Keywords:
formaldehyde indoor air activated carbon fiber O-(23456-pentafluorobenzyl)hydroxylamine derivatization direct thermal desorption capillary gas chromatography
PACS:
X831
DOI:
-
Abstract:
A combined method is proposed here to determinate formaldehyde(HCHO) in indoor air with the derivative reaction of formaldehyde with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine(PFBHA) coated on activated carbon fiber(ACF) carrier at the same time when air samples are collected by direct thermal desorption/capillary gas chromatography.In the experiment section,the correlated conditional experiments are done.Under the optimal conditions,using formaldehyde standard samples and direct thermal desorption/capillary GC analysis,the calibration curve of the formaldehyde concentration and the chromatographic peak area of PFBHA-HCHO oxime is drawn with the linear regression equation,and linear regression coefficient R2 is 0.999 9.The minimum detection limit of formaldehyde is 1.8 ng.The precision test shows that the relative standard deviation of the six-times repeated measurement for formaldehyde standard sample is 0.70%,and the relative standard deviation of the formaldehyde concentration(RSD) is 0.72%.The contrast experiment shows that the method is better in accuracy than that of phenol reagent spectrophotometriy.The experimental data show that the method can be accurately used in measuring the formaldehyde content in indoor air in the range of 0.000 368~0.409 mg/m3.

References:

[1] U S Environmental Protection Agency( EPA) . Health buildings,health people [A]. A Vision for 21st Century, American Medical Association [C]. Washi-ngton, DC,US: EPA Press, 2001. 402 - K - 01 - 003.
[2] American Conference of Governmental Industrial Hygienists( ACGIH) . TLVs and BEIs[A]. Based on the Documentation of the Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices [C]. Cincinnati,OH,United States: ACGIH Press, 2002.
[3] Conolly R B,Kimbell J S, Janszen D, et al. Human respiratory tract concer risks of inhaled formaldehyde: dose-response predictions derived from biologically motivated computational modeling of a combined rodent and human dataset[J]. Toxieol Sci, 2004, 82( 1) : 279 - 296.
[4] 纪迅,高枫,王雨群,等. 建筑装饰污染的危害及其防治研究[R]. 南京: 江苏省建筑工程管理局, 2008 - 2009.
[5] U S Environmental Protection Agency( EPA) . Health advisory for methyl ethyl ketone[R]. Washington,DC: EPA, 1987.
[6] U S Environmental Protection Agency( EPA) . Compendium of methods for the determination of toxic organic compounds in ambient Air [R]. Method TO-11A. Washington,DC: EPA, 1996.
[7] National Institute for Occupational Safety and Health ( NIOSH) . Ketones I, II,methyl ethyl ketone( method 1300,method 2500) [R]. Cincinnati,Ohio: National Institute for Occupational Safety and Health, 1994.
[8] Otson R,Fellin P. A review of techniques for measurement of airborne aldehydes[J]. Sci Tot Environ, 1988, 77: 95 - 131.
[9] Levin J O,Lindahl R. Diffusive air sampling of reactive compounds: A review[J]. Analyst, 1994, 119: 79 - 83.
[10] Wang Qing,O'Reilly John,Pawliszyn J. Determination of low-molecular mass aldehydes by automated headspace solid-phase microextraction with in-fiber derivatization [J]. Journal of Chromatography A,2005,1071 ( 1,2 ) , 147 - 154.
[11] Risticevic S,Vadoud H,Vuckovic N D,et al. Recent developments in solid-phase microextraction[J]. Analytical and Bioanalytical Chemistry, 2009, 393( 3) : 781 - 795.
[12] Steven S H H,Yu Jian-zhen. Feasibility of collection and analysis of airborne carbonyls by on-sorbent derivatization and thermal desorption[J]. Anal Chem, 2002, 74( 6) : 1232 - 1240.
[13] Niri V H,Matehers J B,Musteata M F, et al. Moni-toring BTEX and aldehydes in car exhaust from a gasoline engine during the use of different chemical cleaners by solid phase microextraction-gas chromato-graphy [J]. Water,Air, and Soil Pollution, 2009, 204( 1 - 4) : 205 - 213.
[14] Martos P A,Pawliszyn J. Sampling and determination of formaldehyde using solid-phase microextraction with on-fiber derivatization[J]. Anal Chem, 1998, 70: 2311 - 2320.
[15] 余纯丽,任建敏,傅敏,等. 活性炭纤维的改性及其微孔结构[J]. 环境科学学报,2008,28 ( 4 ) : 714 - 719.
[16] 麻寒娜,朱梦雅,王亚林,等. 活性炭纤维固相微萃取- 气相色谱法测定海水中的硝基苯类和环酮类化合物[J]. 色谱, 2009, 27( 3) : 341 - 345.
[17] Skoog D A,Holler E J,Nieman T A. Principles of Instrumental Analysis[M]. Orlando,FL: Harcourt Brace and Co, 1998.
[18] GB/T18204. 26 - 2001. 公共场所空气中甲醛测定方法[S].
[19] GB50325 - 2001( 2006 版) . 民用建筑工程室内环境污染控制规范[S].
[20] GB/T18883 - 2002. 室内空气质量标准[S].

Memo