Abstract:
To optimize the system performance and reduce the refrigerant charge,the refrigerant conditions of the direct-expansion solar-assisted heat pump water heater(DX-SAHPWH)system are analyzed.Simulation program of the system is coded based on the main components and refrigerant charge mathematical models.Comparisons between the simulation results and experimental measurements show that the model is suitable for predicting the system.Based on calculated results,effects of the water temperature,the refrigerant charge,the compressor motor speed,the solar radiation and the environmental temperature on the refrigerant distribution and migration are obtained.The results show that the 70%~80% refrigerant charge of DX-SAHPWH mostly exists in the condenser and the collector.When system parameters change,the refrigerant redistributes mainly between the condenser and the collector.And the refrigerant mass charge in the compressor and pipes varies slightly.Smaller sizes of condensers and collectors can effectively reduce the refrigerant charge and optimize system performance.

References:

[1] Bin L,Steffen P,Predrag S H,et al.Refrigerant mass migration modeling and simulation for air conditioning systems[J].Applied Thermal Engineering,2011,31(10):1770-1779.
[2]Björk E,Palm B.Refrigerant mass charge distribution in a domestic refrigerator.Part Ⅱ:Steady state conditions[J].Applied Thermal Engineering,2006,26(8-9):866-871.
[3]Larry P,Jun H K,Ben L,et al.Measured effect of airflow and refrigerant charge on the seasonal performance of an air-source heat pump using R-410A[J].Energy and Building,2011,43(7):1802-1810.
[4]Rossi F D,Mauro A W,Musto M,et al.Long-period food storage household vertical freezer:Refrigerant charge influence on working conditions during steady operation[J].International Journal of Refrigeration,2011,34(5):1305-1314.
[5]Ding Guoliang,Ma Xiaokui,Zhang Ping,et al.Practical methods for measuring refrigerant mass distribution inside refrigeration system[J].International Journal of Refrigeration,2009,32(2):327-334.
[6]张月红,徐国英,张小松.太阳能与空气复合源热泵热水系统多模式运行实验研究[J].化工学报,2010,61(2):484-490.
Zhang Yuehong,Xu Guoying,Zhang Xiaosong.Experimental characteristics of solar-air source heat pump water heating system operating in different modes[J].CIESC Journal,2010,61(2):484-490.
[7]钱文波,冯永斌,晏刚.家用空调系统制冷剂充注量的研究[J].制冷与空调,2010,10(2):75-79.
Qian Wenbo,Feng Yongbin,Yan Gang.Study on refrigerant charge of domestic air-conditioning system[J].Refrigeration and Air-conditioning,2010,10(2):75-79.
[8]曲世琳,马飞,吉玉宝,等.非直膨式太阳能-水源热泵地板辐射采暖实验系统研究[J].南京理工大学学报,2010,34(1):141-145.
Qu Shilin,Ma Fei,Ji Yubao,et al.Experiment system analysis of indirect expansion solar assisted water source heat pump radiant floor heating system[J].Journal of Nanjing University of Science and Technology,2010,34(1):141-145.
[9]孔祥强,张东,李瑛,等.直膨式太阳能热泵热水器模拟分析[J].太阳能学报,2010,31(12):1610-1615.
Kong Xiangqiang,Zhang Dong,Li Ying,et al.Simulation analysis on a direct expansion solar assisted heat pump water heater[J].Acta Energiae Solaris Sinica,2010,31(12):1610-1615.
[10]Kong Xiangqiang,Zhang Dong,Li Ying,et al.Thermal performance analysis of a direct-expansion solar-assisted heat pump water heater[J].Energy,2011,36(12):6830-6838.
[11]Lockhart R W,Martinelli R C.Proposed correlations of data for isothermal two-phase,two component flow in pipes[J].Chemical Engineering Progress,1949,45(1):39.
[12]Li Yuwu,Wang Ruzhu,Wu Jingyi,et al.Experimental performance analysis and optimization of a direct expansion solar-assisted heat pump water heater[J].Energy,2007,32(8):1361-1374.
[13]Kheiri A,Feidt M,Boussehain R,et al.Refrigerant charge reduction:On a new design optimization criterion for compact heat exchangers[J].International Journal of Refrigeration,2011,34(6):1462-1470.
[14]Björn P.Refrigeration systems with minimum charge of refrigerant[J].Applied Thermal Engineering,2007,27(10):1693-1701.

Memo

Memo:
-
Last Update: 2013-10-31