|Table of Contents|

Finite element analysis on dynamic characteristics of inductance in pulsed power supply

《南京理工大学学报》(自然科学版)[ISSN:1005-9830/CN:32-1397/N]

Issue:
2014年05期
Page:
658-662
Research Field:
Publishing date:

Info

Title:
Finite element analysis on dynamic characteristics of inductance in pulsed power supply
Author(s):
Yu Xiaohua12Dong Jiannian1Wang Hao1
1.School of Energy and Power Engineering,NUST,Nanjing 210094,China; 2.73198 Unit of PLA,Nanjing 210009,China
Keywords:
electromagnetic launch pulsed power supply current density inductance finite element analysis
PACS:
TM47
DOI:
-
Abstract:
In order to obtain the electromagnetic coupling law in the pulsed power supply module,the dynamic characteristics of the inductance in the module is studied by using the finite element theory.The 3D model of the inductance is established,and the law of the current density distribution on the copper belt of the inductor and the curve of the dynamic inductance value when the pulsed power supply module works are presented.The result shows that:the current concentrate mainly on the center and edges of the copper belt,the inductance increases approximately exponentially with the increase of the frequency,and the inductance value increases while the change rate of the inductance decreases.Before the time of peak current,the change rate of the inductance decreases rapidly.The inductance value is approximately time-constant when the copper thickness is less than 1 mm and the capacitance effect can be neglected.

References:

[1] 吴素文.空心圆柱线圈的电感计算表[J].郑州大学学报(工学版),2003,24(3):106-112. Wu Suwen.Inductance tables of air-cored cylindrical coil[J].Journal of Zhengzhou University(Engineering Science),2003,24(3):106-112.
[2]肖后秀,李亮.脉冲磁体的电感计算[J].电工技术学报,2010,25(1):14-18. Xiao Houxiu,Li Liang.Inductance calculation for pulsed magnets[J].Transactions of China Electrotechnical Society,2010,25(1):14-18.
[3]Qiu Yu,Sebo S A.Accurate evaluation of the magnetic field strength of large substation air-core reactor coils[J].IEEE Transactions on Power Delivery,1998,13(4):1114-1119.
[4]刘志刚,王建华,耿英三,等.干式空心电抗器磁场和电感的计算分析[J].高压电器,2003,39(3):7-11. Liu Zhigang,Wang Jianhua,Geng Yingsan,et al.The calculation of magnetic field and inductance of dry-type air-core reactor[J].High Voltage Apparatus,2003,39(3):7-11.
[5]Ram B S.Inductance and winding eddy loss of air-cored reactors[J].IEE Proceedings on Generation,Transmission and Distribution,1999,146(5):416-420.
[6]Enohnyaket M,Ekman J.Analysis of air-core reactors from DC to very high frequencies using PEEC models[J].IEEE Transactions on Power Delivery,2009,24(2):719-729.
[7]郑莉平,陈静谨.干式空心电抗器磁通量和电感的计算[J].高电压技术,2002,28(10):18-22. Zheng Liping,Chen Jingjin.A calculation method of the flux and inductance of dry-type air reactors[J].High Voltage Engineering,2002,28(10):18-22.
[8]郑莉平,孙强,刘小河,等.干式空心电抗器设计和计算方法[J].电工技术学报,2003,18(4):81-84. Zheng Liping,Sun Qiang,Liu Xiaohe,et al.Design and calculation methods of dry-type air reactors[J].Transactions of China Electrotechnical Society,2003,18(4):81-84.
[9]郑莉平,候浩录,王宏江.空心电抗器电感的解析计算[J].电子器件,2011,34(4):391-394. Zheng Liping,Hou Haolu,Wang Hongjiang.Analytical calculation of the inductance of air-core reactors[J].Chinese Journal of Electron Devices,2011,34(4):391-394.
[10]刘东升.胡国龙,郑泉,等.空心接地电抗器的磁场和电抗计算[J].变压器,2008,45(5):5-7. Liu Dongsheng,Hu Guolong,Zheng Quan,et al.Calculation of magnetic field and reactance of earth reactor with air core[J].Transformer,2008,45(5):5-7.
[11]夏天伟,曹云东,闫英敏.三相干式空心电抗器组等效感抗的计算[J].电工技术学报,1999,14(3):61-64. Xia Tianwei,Cao Yundong,Yan Yingmin.The calculations of three-phase dry air core reactor group equivalent inductive reactance[J].Transactions of China Electrotechnical Society,1999,14(3):6l-64.
[12]夏天伟,闫英敏,曹云东.干式空心电抗器电感的计算[J].变压器,1997,34(2):15-20. Xia Tianwei,Yan Yingmin,Cao Yundong.The inductance calculation of dry-type air-core reactor[J].Transformer,1997,34(2):15-20.
[13]Murgatroyd P N,Walker N J.Frequency-dependent inductance and resistance of foil conductor loops[J].Proceedings of the Institution of Electrical Engineers,1977,124(5):493-496.
[14]El-Missiry M M.Calculations of current distribution and optimum dimensions of foil-wound air-cored reactors[J].Proceedings of the Institution of Electrical Engineers,1977,124(11):1073-1077.
[15]Reeves R.Air-cored foil-wound inductors[J].Proceedings of the Institution of Electrical Engineers,1978,125(5):460-463.

Memo

Memo:
-
Last Update: 2014-10-31