|Table of Contents|

Heuristic algorithm for critical clearing time considering limitingcharacteristics of static var compensator(PDF)

《南京理工大学学报》(自然科学版)[ISSN:1005-9830/CN:32-1397/N]

Issue:
2017年06期
Page:
725-
Research Field:
Publishing date:

Info

Title:
Heuristic algorithm for critical clearing time considering limitingcharacteristics of static var compensator
Author(s):
Jiang NingqiangWang Xiao
School of Automation,Nanjing University of Science and Technology,Nanjing 210094,China
Keywords:
static var compensators limiting characteristics critical clearing time transient stability power systems
PACS:
TM712
DOI:
10.14177/j.cnki.32-1397n.2017.41.06.010
Abstract:
To overcome the difficulty in power system transient stability analysis due to the limiting characteristics of the static var compensator(SVC),a heuristic algorithm is proposed to determine the critical clearing time(CCT)based on the features of SVC susceptance variation during the transients caused by short-circuit.The projection of the fault-on trajectory is calculated,and the CCT along it is determined by the derivative of the capacitive susceptance.The efficiency of transient stability analysis is improved because the transient energy,controlling unstable equilibrium point and the post-fault trajectory need not to be calculated.The analysis result of a three machine system shows that,the relative error of CCT is less than 10%.

References:

[1] 李训铭,李雪,胡勇.矢量控制在动态无功补偿控制器中的应用[J].南京理工大学学报,2005,29(s1):81-84.
Li Xunming,Li Xue,Hu Yong.Application of vector control in dynamic reactive compensation controller[J].Journal of Nanjing University of Science and Technology,2005,29(s1):81-84.
[2]李立,鲁宗相,周双喜,等.柔性交流输电系统设备对电力系统暂态失稳风险的影响[J].电力系统自动化,2012,36(6):11-16.
Li Li,Lu Zongxiang,Zhou Shuangxi,et al.Impact of flexible AC transmission device on power system instability risks[J].Automation of Electric Power Systems,2012,36(6):11-16.
[3]尤彬彬.含SVC的电力系统直接法稳定性分析[D].南京:南京理工大学自动化学院,2016.
[4]Hiskens I A,Hill D J.Incorporation of SVCs into energy function methods[J].IEEE Transactions on Power Systems,1992,7(1):133-140.
[5]Jing C,Vittal V,Ejebe G C,et al.Incorporation of HVDC and SVC models in the Northern State Power Co.(NSP)network; for on-line implementation of direct transient stability assessment[J].IEEE Transactions on Power Systems,1995,10(2):898-906.
[6]Haque M H.Improvement of first-swing stability limit by utilizing full benefit of shunt FACTS devices[J].IEEE Transactions on Power Systems,2004,19(4):1894-1902.
[7]Sebastian B,Garg R.Transient stability analysis of multi-machine power system and first swing stability analysis using SVC[C]//International Conference on Advances in Electrical Engineering.Vellore,India:IEEE,2014:1-6.
[8]Chiang H D.Direct methods for stability analysis of electric power systems[M].Hoboken,New Jersey,USA:John Wiley & Sons,2011.