[1]吕 倩,胡家渝,刘 娟,等.机载热管冷板传热性能与寿命预估试验研究[J].南京理工大学学报(自然科学版),2014,38(01):111-117.
 Lv Qian,Hu Jiayu,Liu Juan,et al.Experimental study on heat transfer performance and life prediction of heat pipe cold plate on board[J].Journal of Nanjing University of Science and Technology,2014,38(01):111-117.
点击复制

机载热管冷板传热性能与寿命预估试验研究
分享到:

《南京理工大学学报》(自然科学版)[ISSN:1005-9830/CN:32-1397/N]

卷:
38卷
期数:
2014年01期
页码:
111-117
栏目:
出版日期:
2014-02-28

文章信息/Info

Title:
Experimental study on heat transfer performance and life prediction of heat pipe cold plate on board
作者:
吕 倩1胡家渝1刘 娟2成丹凤2
1.中国西南电子技术研究所,四川 成都 610036; 2.南京航空航天大学 航空宇航学院,江苏 南京 210016
Author(s):
Lv Qian1Hu Jiayu2Liu Juan2Cheng Danfeng2
1.Southwest China Institute of Electronic Technology,Chengdu 610036,China; 2.College of Aerospace Engineering,Nanjing University of Aeronautics & Astronautics,Nanjing 210016,China
关键词:
热管冷板 温度循环试验 传热性能 寿命预估
Keywords:
heat pipe cold plates temperature cycle test heat transfer characteristics estimated life time
分类号:
TK124
摘要:
为考察热管冷板在机载条件下的适用性,设计一种温度循环试验方案对不同类型及同类型不同配置方式的9种热管冷板进行试验研究。根据温度循环前后红外热像仪测试结果分析不同热管冷板的传热性能差异,并基于试验结果采用阿雷尼乌斯公式进行寿命预估。研究表明:温度循环前后,铝均温板因产生不凝性气体导致传热性能恶化,普通铜水热管冷板与微热管阵列冷板传热性能均未发生改变,可靠性较好; 未发生恶化的热管冷板在最高工作温度下预估寿命至少为6 627 h,可满足使用寿命要求。研究工作可为机载热管冷板的选择与设计提供参考依据。
Abstract:
In order to investigate the applicability of heat pipe cold plate under airborne environmental conditions,a temperature cycle test program is proposed to study the nine kinds of different heat pipe cold plates.According to the results tested by infrared thermal imager before and after temperature cycle,the performance differences of different heat pipe cold plates are analyzed.Based on the test results,the life time is predicted by the Arrhenius equation.The results show that the heat transfer characteristics of vapor chamber is deteriorated due to non-condensable gas generated before and after temperature cycle,but the performance of ordinary copper-water heat pipe cold plate and micro-heat pipe arrays have no change and they have better reliability; the estimated life time of unchanged heat pipe cold plates can be at least 6 627 hours at the highest operating temperature,meeting the life requirements.The research can provide some foundation for the selection and design of the heat pipe cold plate used for cooling the airborne electronic equipment.

参考文献/References:

[1] 赵忠超,叶锐,陈育平,等.高热流密度电子器件冷却用热管散热器传热性能的红外成像研究[J].江苏科技大学学报(自然科学版),2012,26(1):40-44.
Zhao Zhongchao,Ye Rui,Chen Yuping,et al.Research on the heat transfer performance of heat pipe radiator in cooling electronic apparatus with high heat flux by infrared imaging[J].Journal of Jiangsu University of Science and Technology(Natural Science Edition),2012,26(1):40-44.
[2]Garimella S V.Advances in mesoscale thermal management technologies for microelectronics[J].Microelectronics J,2006(37):1165-1185.
[3]Possamai F C,Setter I,Vasiliev L L.Miniature heat pipes as compressor cooling devices[J].Applied Thermal Engineering,2009(29):3218-3223.
[4]张亚平,余小玲,冯全科.热管热性能的实验研究[J].西安科技大学学报,2007,27(2):187-195.
Zhang Yaping,Yu Xiaoling,Feng Quanke.Experiment of heat pipe thermal performance[J].Journal of Xi'an University of Science and Technolofy,2007,27(2):187-195.
[5]余莉,韩玉,曹业玲,等.电子设备散热用平板式热管的实验研究[J].南京航空航天大学学报,2008,40(5):628-631.
Yu Li,Han Yu,Cao Yeling,et al.Experiment investigation on flat-plate heat pipe in cooling electronic equipment[J].Journal of Nanjing University of Aeronautic & Astronautics,2008,40(5):628-631.
[6]田金颖,牛建会.新型热管电子器件散热器的实验研究和数值模拟[J].制冷,2010,29(2):9-14.
Tian Jinying,Niu Jianhui.Experimental study and numerical simulation on a novel heat pipe radiator for electronic element[J].Refrigeration,2010,29(2):9-14.
[7]Nikkanen K,Lu C G,Kawaji M.Effects of working fluid,fill ratio and orientation on looped and unlooped pulsating heat pipes[A].Heat Transfer[C].San Francisco:ASME,2005:593-398.
[8]Jiao A J,Ma H B,Crister J K.Evaporation heat transfer characteristic of a grooved heat pipe with micro-traprzoidal grooves[J].International Journal of Heat and Mass Transfer,2007(50):2905-2911.
[9]Wang Shuangfeng,Chen Jinjian,Hu Yanxin,et al.Effect of evaporation section and condensation section length on thermal performance of flat plat heat pipe[J].Applied Thermal Engineering,2011,31(14/15):2367-2373.
[10]马永昌,张宽峰.热管技术的原理、应用与发展[J].变频器世界,2009(7):70-75.
Ma Yongchang,Zhang Xianfeng.Principle,application and development of heat pipe technology[J].The World of Inverters,2009(7):70-75.
[11]陶汉中.太阳能热水系统用热管的寿命试验方法[A].第十二届全国热管会议论文集[C].深圳:中国工程热物理学会,2010:150-154.

备注/Memo

备注/Memo:
收稿日期:2013-09-05 修回日期:2013-11-03
作者简介:吕倩(1975-),女,高级工程师,主要研究方向:电子设备热设计,E-mail:lvqian1975@163.com。
引文格式:吕倩,胡家渝,刘娟,等.机载热管冷板传热性能与寿命预估试验研究[J].南京理工大学学报,2014,38(1):111-117.